![]() ![]() This floor will be even worse, because both ends of the floor joists will be supported by bouncy, low moment of inertia LVLs.ĭon't take my word for this, make the calcs using only known dead loads, and the 50 PSF floor live load (forget about wind load for now). ![]() This is not magic, it's about a beam's moment of inertia which is sensitive to beam depth. Any ratio over about 20 begins to act like a "flat spring" which will make the floor's serviceability seem "bouncy" to occupants. The reason, consider the LVL's span-to-depth ratio (420" / 16" ≈ 26). In all likelihood the floor will fail because of excessive deflection from even the most basic loads. Save yourself time and "hand-wringing" over how to precisely apply the loads. I'm accurately calculating all loads before recommending a different solution. ![]() RE: Long Span (35') LVL Beam Design skeletron (Structural) 27 Dec 19 22:34įour 2x16 LVLs fastened together and 35 ft in length. Not many LVL manufacturers have spans listed that high in their literature. Looking at the roof framing, is the rafter bracing wall - that sits directly onto the beam - picking up much load? or does most of the roof load go to the exterior walls? I'm making sure I'm accurately calculating all loads before recommending a different solution (Being that the beam is currently installed).ģ5' is a heck of a span to begin with. My STAAD model results are currently showing Fail, and also a mid-point Deflection of about 3" (L/140). Rather than Model the entire building, I modeled just column/beam frame (diagram attached), and am wanting to put the distributed dead, live and wind load on the beam for my analysis. The rest of the ceiling is framed laterally with 2x10s 16" o.c. They are supported at the ends by two 5.5"x5.5"x0.25" Square HSS. There are two beams in question, each comprised of Four 2x16 LVLs fastened together and 35 ft in length. MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lbs.I was contacted by a building owner that wanted to build out his attic space into offices, and needed to ensure that 2 installed beams (Beam were never previously Engineered) are adequate to handle the additional live and dead loads. TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLY a, b, c, f, g, h (Floor Live Load ≤ 40 psf, Roof Live Load ≤ 20 psf) MEMBER & SPACING Floor cantilevers supporting an exterior balcony are permitted to be constructed in accordance with Table R502.3.3(2). Floor cantilevers constructed in accordance with Table R502.3.3(1) shall be permitted where supporting a light-frame bearing wall and roof only. Dead load limits for townhouses in Seismic Design Category C and all structures in Seismic Design Categories D 0, D 1 and D 2 shall be determined in accordance with Section R301.2.2.2.1.įLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360) b JOIST SPACING (inches)įloor cantilever spans shall not exceed the nominal depth of the wood floor joist.Note: Check sources for availability of lumber in lengths greater than 20 feet. TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360) a JOIST SPACING (inches)įor SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. ![]() The allowable span of ceiling joists that support attics used for limited storage or no storage shall be determined in accordance with Section R802.4. Table R502.3.1(1) shall be used to determine the maximum allowable span of floor joists that support sleeping areas and attics that are accessed by means of a fixed stairway in accordance with Section R311.7 provided that the design live load does not exceed 30 pounds per square foot (1.44 kPa) and the design dead load does not exceed 20 pounds per square foot (0.96 kPa). ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |